{"title":"OPU Needles and Embryo Transfer Catheters","description":"","products":[{"product_id":"kitazato-pre-curved-catheters","title":"Kitazato Pre-Curved Catheters","description":"Kitazato offers a wide variety of embryo transfer catheters capable of covering any need under any circumstance. Select from a broad range of embryo transfer catheters designed to meet all healthcare requirements. Kitazato design their catheters to offer preferred handling, accuracy and control during embryo transfer procedures.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSummary\u003c\/strong\u003e\u003cbr\u003eThanks to its 30º curve and its characteristic flexibility, the Kitazato Precurved Catheters provide an easy and atraumatic navigation through the cervical channel in any kind of anatomy\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eTip with a rounded bulb to reduce trauma during the insertion.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003e30º curvature and high flexibility for easy navigation in the cervical canal in all kinds of anatomy.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eSupported catheter to facilitate insertion in the guide.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eSuperior smoothness and friction-free materials for the comfort of the patient during the transfer.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eApproximation marks on the guide and catheter for greater precision in the transfer.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eStopper for holding the guide at the desired depth.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eObturator available for keeping the guide free of cervical mucus during the insertion.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eStylets available for difficult transfers.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAvailable in 3Fr and 4Fr in lengths of 22cm and 25cm.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAvailable with a straight tip, without bulb.\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e","brand":"Kitazato","offers":[{"title":"Default Title","offer_id":51204599447881,"sku":"SKU 13014","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0891\/7476\/9993\/files\/precurved_lengths.jpg?v=1732126223"},{"product_id":"kitazato-single-lumen-aspiration-needles","title":"Kitazato Single Lumen Aspiration Needles","description":"Designed and manufactured in compliance with the highest quality standards\u003cbr\u003e- Thin Wall design\u003cbr\u003e- Triple Cut blade\u003cbr\u003e- Echogenic Marking to the tip\u003cbr\u003e- Gauge range from 16G to 21G\u003cbr\u003e- Different tubing lengths\u003cbr\u003eManufactured from steel of excellent quality, its triple cut blade provides a fast puncture, minimising\u003cbr\u003edamage to the ovarian tissue. The excellent control of the puncture allows the operation time to be\u003cbr\u003ereduced, retrieving oocytes in the best possible conditions.\u003cbr\u003e\u003cbr\u003eThe Kitazato needles have a “Thin Wall” design which offers, with the same external diameter, an increased internal diameter with respect to the rest of the puncture needles on the market. In this way, Kitazato allows work to be carried out with needles with smaller external diameter, and thus reduces the possibility of bleeding and the risk of lesions in the uterine lining while minimising stress in the oocyte during the aspiration.\u003cbr\u003e\u003cbr\u003eKitazato range of diameters, from 16 Gauge to 21 Gauge, is largest on the market, offering ideal options for working with patients with low response in natural cycles, allowing the follicular aspiration to be carried out without anaesthetic with the smallest diameters.\u003cbr\u003e\u003cbr\u003eHighly visible echogenicity is achieved by the ECHO Markings running to the tip of the needle. This marking is etched smooth into the metal minimising trauma.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eTip with echogenic marking - guarantees high visibility for the correct approach to the follicle during oocyte recovery.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003e“Thin Wall” design - provides a greater internal diameter. Reduces stress to the oocyte during aspiration and allows work with needles with smaller external diameter, reducing trauma to the patient.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eTriple cut blade - ensures fast and effective puncture which minimises lesions to tissue.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eHandle with positioning marking - provides control throughout the oocyte recovery process and helps to control the position of the needle blade.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eSilicon bung with syringe connection - allows cleaning the follicle or cleaning the needle. Prevents any negative effect derived from a potential patient allergy to latex.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eDifferent lengths available for aspiration tubes.\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cstrong\u003eQuality Control:\u003c\/strong\u003e\u003cbr\u003eCytotoxicity\u003cbr\u003eEndotoxin\u003cbr\u003eIntracutaneous reactivity\u003cbr\u003eMouse embryo assay (MEA)\u003cbr\u003eSensitization\u003cbr\u003eSterility\u003cbr\u003e\u003cbr\u003eComposition: stainless steel SUS304","brand":"Kitazato","offers":[{"title":"Default Title","offer_id":51204599841097,"sku":"SKU 13042","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0891\/7476\/9993\/files\/Single-lumen_needle-pump_3.jpg?v=1732126231"},{"product_id":"kitazato-ryden™-et-catheter-precision-and-control-redefining-embryo-transfer","title":"Kitazato RYDEN™ ET Catheter: Precision and Control Redefining Embryo Transfer","description":"\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eEmbryo transfer is the most delicate step in the IVF journey. You get one chance to deliver the embryo into the uterine cavity with maximum precision, minimum trauma, and full confidence in what you see on ultrasound. The RYDEN™ ET catheter has been engineered to give you that level of control, clarity, and predictability on every case. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-outline-level: 2;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eElevate your embryo transfer technology\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eEmbryo Transfer (ET) is universally recognised as the final, and most crucial, step in the in vitro fertilisation (IVF) process. For successful outcomes, the embryo must be placed in the optimal zone of the uterine cavity without provoking trauma or contractions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eThe RYDEN™ ET catheter is Kitazato’s latest evolution in precurved ET catheter systems. Developed in close collaboration with IVF clinicians, it addresses the two biggest demands in reproductive medicine today: \u003cb\u003eoperational control\u003c\/b\u003e and \u003cb\u003esuperior visualization\u003c\/b\u003e under ultrasound. Intended for ultrasound-guided introduction of embryos, this echogenic ET catheter supports precise navigation and placement in even the most challenging cases.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eRYDEN™ is more than a device. It is a supported and fully echogenic solution that redefines embryo transfer technology and helps clinics standardise procedures for consistently successful outcomes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-outline-level: 2;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eThe hybrid advantage: control without trauma\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eHistorically, clinics have had to choose:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l7 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eSoft ET catheter for minimal trauma but poorer control and higher risk of technical failure.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l7 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eStiffer catheter for better navigation and rigidity but greater risk of endometrial irritation.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eThe RYDEN™ catheter breaks this compromise. Its hybrid design combines structural metallic support with a highly atraumatic profile, so you no longer have to trade safety for control.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eBy integrating metallic support for enhanced control into the outer structure, the RYDEN™ catheter gives the operator a predictable feel in the hand while preserving a gentle, patient-friendly tip. This balance is what allows clinicians to maintain consistency, protect the implantation environment, and move toward more reliable, clinic-wide successful outcomes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-outline-level: 2;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eMetallic support for enhanced control and precise navigation\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eThe RYDEN™ system incorporates an outer metallic support for enhanced control, giving the ET catheter the ideal degree of rigidity without sacrificing sensitivity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo2; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eHow it works:\u003cbr\u003eA dedicated metallic support layer runs along the guide, providing superior rigidity and control for precise catheter manipulation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo2; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eWhy it matters clinically:\u003cbr\u003eThis structure ensures predictable navigation through complex or constricted cervical anatomy, reducing technical failures, the need for catheter exchange, and procedure time.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eIn practice, this means the physician can steer the catheter with more precision, particularly in difficult anatomy, while maintaining a smooth trajectory into the uterine cavity. The end result is a more controlled embryo transfer that supports your best possible implantation rates.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-outline-level: 2;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eFully echogenic design for unmatched clarity under ultrasound\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eRYDEN™ features a fully echogenic design: the guide, guide tip, and inner catheter are all designed to be fully echogenic. This provides truly superior visualisation on ultrasound from the moment the catheter enters the cervix to the final deposition of the embryo-containing droplet.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eThis high level of echogenicity delivers a new level of clarity:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eYou can continuously track catheter alignment and depth.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eYou can confirm the droplet position precisely 6–10 mm from the fundus.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eYou can reliably avoid fundal contact, which is known to be associated with lower clinical pregnancy rates.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eWith this fully echogenic ET catheter, clinicians gain real-time feedback that directly supports more precise, controlled, and reproducible embryo transfer procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-outline-level: 2;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eAtraumatic guide with bulb tip: protecting the implantation environment\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eIn embryo transfer, the way you enter the cervix can be as important as where you finish. RYDEN™ incorporates an atraumatic guide with a soft bulb tip and echogenic ring to support gentle, safe passage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eThis atraumatic bulb tip is specifically designed to reduce contact trauma that may trigger uterine contractions or disturb the endometrium. When combined with the system’s metallic support and precise navigation, the guide helps transform difficult transfers into smooth, low-stress procedures for both clinician and patient.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eFor clinics focused on patient comfort and careful protection of the implantation environment, this combination of atraumatic characteristics and high-end embryo transfer technology is a significant advantage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-outline-level: 2;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003ePrecurved guide with memory for individual anatomy\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eEvery patient’s cervical and uterine anatomy is unique. RYDEN™ addresses this reality with a precurved guide that includes a guide with memory feature.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eThe precurved design allows the clinician to customise the curvature to suit individual anatomy without losing that shape during insertion. This:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l5 level1 lfo4; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eReduces the need for forceful manipulation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l5 level1 lfo4; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eMinimises friction within the cervical canal.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l5 level1 lfo4; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eSupports smooth, precise advancement into the uterine cavity.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eBecause the precurved structure and guide with memory work together, the catheter follows a predictable path, letting the operator focus on precise placement rather than fighting the device.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-outline-level: 2;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eErgonomic workflow: preloaded catheter into the guide\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eRYDEN™ has been designed not only for clinical performance, but also for a clean, efficient lab workflow. The handle includes a large, user-friendly opening that simplifies handling and loading.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eThe system is delivered as a preloaded catheter into the guide, meaning the inner catheter is ready for use directly in the sterile pack. This reduces the number of steps needed during preparation and helps minimise contamination risk at setup.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eFor busy IVF laboratories, this ergonomically optimised workflow translates into:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l2 level1 lfo5; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eFaster preparation time.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l2 level1 lfo5; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eFewer handling errors.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l2 level1 lfo5; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eA more standardised process across the team.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-outline-level: 2;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eOptimised placement for maximal implantation potential\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eThe final position of the transferred air bubble is recognised as an independent predictor of the clinical pregnancy rate. With RYDEN™, fully echogenic design and superior visualization make it straightforward to confirm exact positioning.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eUnder ultrasound guidance, the operator can:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l4 level1 lfo6; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eTrack the catheter’s course through the uterine cavity.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l4 level1 lfo6; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eVisually confirm the embryo-containing micro-droplet is deposited in the optimal zone.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l4 level1 lfo6; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eAvoid trauma and fundal contact that may compromise implantation.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eThis meticulous, precise approach protects the implantation environment from mechanical insult and supports the lab’s goal of maximising implantation and ongoing pregnancy rates in every embryo transfer.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-outline-level: 2;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eBuilt on Kitazato IVF quality and innovation\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eThe RYDEN™ catheter is part of the proven Kitazato IVF portfolio of embryo transfer and insemination catheters. Kitazato is recognised worldwide for high quality standards in reproductive medicine and for its commitment to continuous innovation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eKitazato offers advanced ET catheter systems built for consistency and safety. In fact, Kitazato offers a wide variety of solutions designed to support a wide variety of embryo transfer protocols, from straightforward cases to technically challenging procedures. This allows clinics to match the right ET catheter to the right clinical scenario, without sacrificing quality or control.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eWhen you choose RYDEN™, you are choosing a device that sits within a mature, trusted ecosystem of embryo transfer technology developed specifically for demanding IVF programmes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm; line-height: normal;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-outline-level: 2;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eTechnical specifications and ordering information\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eThe RYDEN™ ET catheter is a sterile, single-use ET catheter system with CE Mark certification, manufactured to international standards of quality and safety.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eAll configurations share a consistent 3 Fr diameter for an atraumatic insertion profile and reliable handling characteristics:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cb\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eConfiguration options\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l6 level1 lfo7; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eStandard Kit with Guide, 22 cm, 3 Fr – Echogenic supported catheter with guide (Order No: 213312)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l6 level1 lfo7; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eStandard Kit with Guide, 25 cm, 3 Fr – Echogenic supported catheter with guide (Order No: 213355)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l6 level1 lfo7; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eKit with Guide and Obturator, 22 cm, 3 Fr – Echogenic supported catheter and guide with obturator (Order No: 223312)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l6 level1 lfo7; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eKit with Guide and Obturator, 25 cm, 3 Fr – Echogenic supported catheter and guide with obturator (Order No: 223355)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l6 level1 lfo7; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eStylet Accessory 22 cm – Soft stylet for guide (Order No: 244017)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l6 level1 lfo7; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eStylet Accessory 25 cm – Soft stylet for guide (Order No: 244020)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eThese configurations give your clinic the flexibility to integrate RYDEN™ into both single-step and double-step embryo transfer protocols while maintaining the same core performance characteristics.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-outline-level: 2;\"\u003e\u003cb\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eWhy choose the RYDEN™ catheter for your clinic?\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eBy combining metallic support, fully echogenic design and an atraumatic, precurved guide, the RYDEN™ catheter gives your team a genuinely modern embryo transfer technology platform:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l1 level1 lfo8; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eControl and precision\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003e\u003cbr\u003eMetallic support and optimised rigidity enable precise steering, predictable navigation, and consistent placement in the optimal zone.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l1 level1 lfo8; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eClarity under ultrasound\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003e\u003cbr\u003eA fully echogenic design provides superior visualization of both guide and inner catheter throughout the procedure.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l1 level1 lfo8; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eComfort and safety\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003e\u003cbr\u003eAtraumatic bulb tip, gentle profile, and controlled passage help protect the endometrium and reduce contraction risk.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l1 level1 lfo8; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eEfficient workflow\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003e\u003cbr\u003ePreloaded catheter into the guide and ergonomic handle support smooth laboratory practice and minimise handling errors.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eFor IVF programmes seeking to standardise embryo transfer, reduce technical failures, and push for the highest possible implantation rates, the RYDEN™ catheter offers a truly supported and fully echogenic solution.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm; line-height: normal;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-outline-level: 2;\"\u003e\u003cb\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eReady to advance your IVF outcomes?\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003ePut RYDEN™ at the centre of your embryo transfer strategy and give your team the tools they need to deliver consistently successful outcomes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cb\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003eDownload the informational flyer\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-IE;\"\u003e\u003cbr\u003eView the full technical specifications and configuration matrix for the \u003ca title=\"Kitazato Ryden Embryo Transfer Catheter\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0891\/7476\/9993\/files\/Flyer_RYDEN_ET_web.pdf?v=1764445621\"\u003eRYDEN™ ET catheter\u003c\/a\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"Mitrone Healthcare Ltd","offers":[{"title":"Default Title","offer_id":53425880662345,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0891\/7476\/9993\/files\/RYDEN_OBTURADOR_SET3_1.jpg?v=1765917373"}],"url":"https:\/\/www.mitrone.ie\/collections\/opu-needles-and-embryo-transfer-catheters.oembed","provider":"Mitrone Healthcare Ltd","version":"1.0","type":"link"}